RMG88.62C2 Control Box
Riello RMG88.62C2 Control Box
Microcontroller-based burner controls for the supervision of single- or multistage forced draft gas burners in intermittent operation. Maximum capacity above 120 kW when firing on gas.
The control box is a control and supervision system of medium and large capacity forced draught burners, for intermittent operation (at least one controlled shutdown every 24 hours).
The burner controls are designed for the startup and supervision of single- or multistage forced draft burners in intermittent operation. The RMG88.62 is for forced draft gas burners.
When firing on gas, the flame is supervised with an ionization probe or flame detector QRA... (with ancillary unit AGQ2...A27).
- Forced draft burners to EN 676
- Burner controls to EN 298
Technical Data
Mains Voltage | AC 230V -15% / +10% |
---|---|
Mains Frequency | 50/60 Hz ±6% |
Built in Fuse | T6.3H 250V |
Energy consumption | 20 VA |
Weight | approx. 260g |
Protection Level | IP20 |
Safety Class | I |
Tightening torque of M4 screw | Max. 0.8 Nm |
Allowed Cable Length | |
Thermostat | max. 20m at 100 pF/m |
Air pressure switch | max. 1m at 100 pF/m |
CPI | max. 1m at 100 pF/m |
Gas pressure switch | max. 20m at 100 pF/m |
Flame detector | max. 1m |
Remote reset | max. 20m at 100 pF/m |
Environmental Conditions | |
Storage | DIN EN 60721-3-1 |
Climatic conditions | Class 1K3 |
Mechanical conditions | Class 1M2 |
Temperature range | -20 - +60°C |
Humidity | < 95% RH |
Riello RMG88.62C2 Control Box
Microcontroller-based burner controls for the supervision of single- or multistage forced draft gas burners in intermittent operation. Maximum capacity above 120 kW when firing on gas.
The control box is a control and supervision system of medium and large capacity forced draught burners, for intermittent operation (at least one controlled shutdown every 24 hours).
The burner controls are designed for the startup and supervision of single- or multistage forced draft burners in intermittent operation. The RMG88.62 is for forced draft gas burners.
When firing on gas, the flame is supervised with an ionization probe or flame detector QRA... (with ancillary unit AGQ2...A27).
- Forced draft burners to EN 676
- Burner controls to EN 298
Technical Data
Mains Voltage | AC 230V -15% / +10% |
---|---|
Mains Frequency | 50/60 Hz ±6% |
Built in Fuse | T6.3H 250V |
Energy consumption | 20 VA |
Weight | approx. 260g |
Protection Level | IP20 |
Safety Class | I |
Tightening torque of M4 screw | Max. 0.8 Nm |
Allowed Cable Length | |
Thermostat | max. 20m at 100 pF/m |
Air pressure switch | max. 1m at 100 pF/m |
CPI | max. 1m at 100 pF/m |
Gas pressure switch | max. 20m at 100 pF/m |
Flame detector | max. 1m |
Remote reset | max. 20m at 100 pF/m |
Environmental Conditions | |
Storage | DIN EN 60721-3-1 |
Climatic conditions | Class 1K3 |
Mechanical conditions | Class 1M2 |
Temperature range | -20 - +60°C |
Humidity | < 95% RH |
Datasheets |
---|