HI-700 Ammonia Low Range Checker®HC Colorimeter (0.00 to 3.00 ppm)

The Hanna Instruments HI-700 Ammonia Low Range Checker®HC is a simple, accurate and cost-effective handheld colorimeter for measuring low ranges of ammonia in fresh water. Designed as a more accurate alternative to chemical test kits, the HI-700 delivers quick results in four easy steps and is dedicated to a single parameter for straightforward, reliable operation. Its small palm-sized design makes it ideal for use in the field, in the laboratory or at the aquarium.

The HI-700 uses an adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method. The reaction between ammonia and reagents produces a yellow tint in the sample which the Checker®HC measures accurately. The unit is supplied with sample cuvettes, a starter pack of 25 ammonia LR reagent tests (HI-700-25), a battery, instruction manual and quick start guide. Additional reagents and the calibration check set HI-700-11 are available separately. Please download and read the relevant Safety Data Sheet before handling reagents.

Key Features
  • Ammonia measurement range 0.00 to 3.00 ppm in fresh water
  • Accuracy ±0.05 ppm ±5% of reading
  • More accurate than chemical test kits — four simple steps to a result
  • Dedicated single parameter instrument for ease of use
  • Small palm-sized design — ideal for field and laboratory use
  • Built-in timer for timed reaction readings
  • Auto power off after 10 minutes of inactivity
  • Single AAA battery powered
Typical Applications
  • Freshwater aquariums
  • Water quality monitoring
  • Wastewater testing
  • Environmental monitoring
  • Education

Product Specifications
Model HI-700 Checker®HC
Parameter Ammonia (low range, fresh water)
Range 0.00 to 3.00 ppm
Accuracy ±0.05 ppm ±5% of reading
Method Adaptation of ASTM D1426-92, Nessler method
Battery Type 1 x AAA
Auto Power Off After 10 minutes of inactivity
Reagents HI-700-25 (x25 tests, included as starter kit)
Calibration Check Set HI-700-11 (sold separately)
Supplied With Sample cuvettes with caps (x2), HI-700-25 ammonia LR reagent starter kit (x25 tests), battery, instruction manual, quick start guide
How to Use
  1. Zero the Checker®HC with your cuvette and a 10ml water sample inside.
  2. Remove the cuvette and add the reagent.
  3. Place the cuvette back into the Checker®HC.
  4. Press the button and read the result.