Turbine Type Warm Water Meter
DN50-DN200
- Hermetically sealed register (IP68)
- Display on 7 drums (5 for m3, 3 for litres)
- Magnetic protection
- DN50-DN200
- Register may be rotated through 360°
- Complete with pulse output as standard
- GG25 Cast Iron housing
- Powder coating ensures maximum corrosion protection
- Low head loss
- Water temperature up to 30°C
- M.I.D Approved as standard
Technical Specifications
NOMINAL DIAMETER | DN | MM | 50 | 65 | 80 | 100 |
Nominal Flow Rate | Q3 | M3/h | 25 | 40 | 63 | 100 |
Maximum Flow Rate | Q4 | m3/h | 32,250 | 50 | 78,750 | 125 |
Minimum Flow Rate | Q1 | l/h | 0,3125 / 0,397 | 0,50 | 0,7875 | 1,250 |
Transitional Flow Rate | Q2 | l/h | 0,5,0,635 | 0,800 | 1,260 | 2 |
Maximum Working Pressure | Pmax | bar | 16 | 16 | 16 | 16 |
Pressure Loss | Δ P | bar | 0,25 | 0,25 | 0,25 | 0,25 |
Maximum Working Temperature | Tmax | °C | 90 | 90 | 90 | 90 |
Measuring Range | Q3 / Q1 | R | 80 / 63 | 80 / 63 | 80 / 63 | 80 / 63 |
Overall Length | L | mm | 200 | 200 | 225 | 250 |
Maximum Register Indication | m3 | 9.999.999 | 9.999.999 | 9.999.999 | 9.999.999 | |
Verification Scale Interval | l | 0,001 | 0,001 | 0,001 | 0,001 | |
Total Height | H | mm | 128 | 128 | 128 | 175 |
Height to Centerline | h | mm | 82 | 90 | 100 | 110 |
Nominal Installation Diameter | DN | mm | 50 | 65 | 80 | 100 |
Weight | - | kg | 11 | 13 | 16 | 19 |