Hot Water Flow Meters

"NUBIS" HOT WATER METER

PROPELLER WATER METER FOR HOT WATER 130°C WITH PULSE TRANSMITTERS

Features 

  • Permanent and efficient contruction, ensuring the flow of water in low loss of pressure and easiness in assembly in random waterworks installations.
  • Lowered weight of water meter.
  • Interchangeable and unified metering layer fitting to several sizes of body and assuring optimal water meter management.
  • Standard water meter in suitable for remote reading in AMR system.
  • The possibility of mounting the water meter in the intermediate position without the influence on the metrological parameters, larger possibilities in designing and modernising new used water meters connections.
  • Very good anti-corrosive and mechanical qualites of paint coat (powder paint-epoxy).
Nominal Diameter DN mm 50 65 80 100 125 150 200

Temperature Class

(working temperatures range)

T30 (0.1 ÷ 30°C),

T50 (0,1 ÷ 50°C)

 

MWN (without transmitter)

or MWN (with transmitter) in NK, NO, NKO, NKOP option)

Maximum Flow Rate Q4 m3/h 31.25 50 78.85 125 200 312.5 500
Maximum Working Flow Rate Q3 m3/h 25 40 63 100 160 250 400
Transitional Flow Rate Q2 m3/h 1 1.6 2.52 4 6.4 10 16
Minimum Working Flow Rate Q1 m3/h 0.625 1 1.575 2.5 4 6.25 10
Starting Flow Rate - m3/h 0.25 0.3 0.35 0.6 1.1 2 4
R Measuring Rate Q3/Q1 - 40 40 40 40 40 40 40
Coefficient Q2/Q1 -              
NUBIS HOT WATER METER DIAGRAM L mm 200 200 225 / 200*** 250 250 300 350
h mm 72 83 95 105 120 135 160
H mm 187 197 219 229 257 357 382
H1*** mm 287 297 239 349 377 582 607
D2 mm 165 185 200 220 250 285 340
Weight - Without Transmitter   kg 9.9 10.6 13.3 / 13.8*** 15.6 18.1 40.1 51.1
Weight - With Transmitter NK / NO   10.3 11 13.7 / 14.2*** 16 18.5 40.5 51.5

* Quality: NK- Reed Switch transmitter, NKP- water meter adapted for Reed Switch, NO- optoelectronic transmitter, NKO- optoelectronic and Reed Switch transmitter, KNOP- water mater adapted for optoelectronic and Reed Switch transmitter.

** Only for T30 and T50.

*** On request.

**** Space for measuring insert removal.

TFlange drilling according to PN-EN 1092-2 (PN10), DIN2532, DIN2501 (NP10), BS4504 (NP10) on special request PN16 and PN25 quality for chosen sizes. 

 