Woltman Type Hot Water Flange
CAST IRON BODY WITH FLANGE CONNECTIONS
The Kent H4300 (WPH) is a Woltman-type horizontal vane hot water meter particularly suited to the high and sustained flows of bulk metering to a maximum temperature of 130°C.
A Magnetic drive between the measuring element and counter reduces the number of working parts in contact with water and the corrosion and heat resistant components guarantee excellent measuring properties, reliability and a long service life.
Pulser designed for use with H4300 (WPH) meters offer a choice of outputs for a wide veriety of applications including revenue billing, automatic meter reading, data logging and process control applications.
Two types of pulser are available : Opto-electronic and Reed-switch. Both are of durable design and contruction and can be easily fitted on site without disturbing the calibration seal or interrupting the water supply.
Features & Benefits
- Hermetically Vacuum sealed dry dial register
- Easy to read counter
- Leak-Proof construction
- Optional pulse output facility
Pressure & Temperature
- Pressure Range up to 16 Bar
- Temperature Range up to 130°C

SIZE | A | B | C | D |
DN50 | 200 | 165 | 234 | 75 |
DN65 | 200 | 185 | 234 | 84 |
DN80 | 225 | 200 | 234 | 92 |
DN100 | 250 | 220 | 234 | 118 |
DN150 | 300 | 285 | 252 | 143 |
DN200 | 350 | 340 | 252 | 180 |
Specifications | DN | 50 | 65 | 80 | 100 | 150 | 200 |
---|---|---|---|---|---|---|---|
Max Continuous Flow Rate ±3% | m3/h | 15 | 25 | 40 | 60 | 150 | 250 |
Min Continuous Flow Rate ±3% | m3/h | 2 | 3 | 4 | 6 | 20 | 20 |
Min Continuous Flow Rate ±5% (Horizontal) | m3/h | 1 | 1.6 | 2 | 2.4 | 4 | 8 |
Output Pulse Option 1 (Reed Switch) | litre/pulse | 100⁄1 | 100⁄1 | 100⁄1 | 100⁄1 | 1000⁄1 | 1000⁄1 |
Output Pulse Option 2 (Reed Switch) | litre/pulse | 1000⁄1 | 1000⁄1 | 1000⁄1 | 1000⁄1 | 10000⁄1 | 10000⁄1 |
Output Pulse (Opto Switch) | litre/pulse | 1⁄1 | 1⁄1 | 1⁄1 | 1⁄1 | 10⁄1 | 10⁄1 |